Concrete testing instrument
Cement, cement slurry test equipment
Mortar test instrument
Asphalt test equipment
Asphalt grease test equipment
Universal, pressure, testing machine series
Geotechnical test equipment
Constant temperature and humidity curing instrument
Electronic balance, test mode series
Subgrade, pavement, field testing instruments
CA mortar instrument
Geosynthetics testing instrument
Nondestructive testing equipment
Linoleum, waterproof coil test equipment
Rock aggregate, tunnel test instrument
Building energy saving. Insulation material testing instrument
Brick / Brick Ceramic Instrument Series
Glass, energy-saving testing equipment
Anti-bending, anti-compression, anti-split fixture series
Longer series
Tianjin Huatong Experimental Instrument Factory Contact: Manager Wang Sales Tel: 022-27361556
Sales Phone: 022-27641869
Mobile: 13502140666
Address: Sanyuancun Street, Nankai District, Tianjin
technical article
Position-> Home > Technical Articles > Installation and use method of disc type stone wear-resistant hardness coefficient K

Installation and use method of disc type stone wear-resistant hardness coefficient K dry grinding tester


installation:
This machine is an integrated structure, which is required to be placed on the concrete floor of the voucher to ensure that the horizontal slope of the disc is less than 1% so that it can rotate lightly around the mandrel.
Instructions:
Before starting the machine, you must be familiar with the structure of the machine, check whether the electrical appliances are intact and the grounding is reliable, and start the machine with manual buttons.
The operation method of the machine's pre-supported counter is as follows:
1. Preset number of revolutions.
① Press and hold the clear button.
② Colleagues press the preset button to preset the required number of revolutions.
2. Turn on the power switch.
3. Press the start button, the machine will start to run, the machine will automatically stop when it reaches the preset number of revolutions. If you need to stop in the middle, you can press the stop button, continue to run, you can press the start button, the counter can continue to count up.
4. To use the machine again, first press the clear button, check the preset number, and then press the start button.
5. The manual button is used to jog the machine, and the counter does not count when jogging.
6. After shutdown, please cut off the power in time.
Unknown Views: Print this pageClose window